Vacuum filtration is a popular separating method to remove a solid from a liquid in modern labs. When we put the vacuum filtration into practice, the solution can be unsaturated, saturated, or supersaturated. The solid which will be separated is dissolved in a solution, and the solid concentration in the liquid is different. A vacuum filter is a device we can use to separate the solids from the liquid by forcing the liquid through the filter by vacuum from the vacuum pump.
Generally, we use vacuum filtration when collecting recrystallized solids. The particles dissolved in water or other solvents will be recovered and recrystallize by heating while the liquid is evaporated during the process of vacuum filtration.
We can also use vacuum filtration to separate solids from liquid solutions. Vacuum filtration is perfect for solutions with suspended particles. If the solutions are unsaturated with the solid dissolved in, some form of chemical treatment or heating is required before the process of vacuum filtration.
The amount of solid collected while vacuum filtrating is related to the pore size of the filter paper that is less than a micrometer in diameter. We may collect a few particles if the pore size of the filter paper is right though vacuum filtration is not suitable for saturated solutions.
₹ 12500 / Piece Get Latest Price
| Filter Size | 90 mm |
| Connection Type | Hose Barb |
| Holder Material | Stainless Steel |
| Usage/Application | Laboratory liquid and gas |
| Finishing Type | Mirror Polish |
| Inlet Pressure | 0.49 MPa |
| Filtration Area | 2.1,12.5 cm2 |
| Filter Diameters | 25mm,47mm |
Minimum order quantity: 10 Piece
This 47mm in-line holder (Model IFH47) is available in both type 316 stainless steel. The PTFE coated support screen prevents the sticking of the membrane during autoclaving. The back-pressure support screen protects the filter from rupture during reverse pressure surges. Upstream vent enables venting at any time during filtration. The dual sealing system compresses filter to ensure no lateral wicking/leaking. The locking ring enables filter changes without disconnecting from lines. Unit comes standard with silicone o-ring and FPM vent o-ring. When filtering gases, it is recommended that a second support screen be used upstream of the membrane. Replacement parts and alternate o-ring materials are available.
Applications:
₹ 12500 / Unit Get Latest Price
| Membrane dia | 47 mm |
| Funnel volume | 1000 ml |
| Material | Stainless steel |
| Vacuum Pump- | Oil Free Vacuum Pump 15 LPM |
| Filter Holder- | Stainless Steel Filter Holder 1000 ml |
| Membrane Filter- | Membrane Filter 47mm x 0.45um |
| Glass Flask- | Glass Flask 1L |
| SS Forceps- | SS Forceps |
Minimum order quantity: 10 Unit
Description :
Sample And Mobile Phase Filtration Are Simple, Economical Practices That Serve To Extend The Life Of Consumable HPLC Parts, Decrease System Wear And Tear, And Preserve The Integrity Of The HPLC System.
Serious Problems When Operating A HPLC System Can Be Avoided By Performing Routine Maintenance. Most HPLC Part Replacement Tasks, Such As Changing Pump Seals, Are Readily Recognized As Necessary Maintenance; However, Mobile Phase And Sample Filtration Are Also Maintenance Practices. Routine Sample And Mobile Phase Filtration Are Simple, Inexpensive, And Convenient Ways To Decrease HPLC Problems.
Regardless Of The Technical Intricacies And Cost Of The System Chosen, All HPLC Systems Have The Same Basic Components, Indicated In Figure 1. A Basic HPLC System Consists Of A Solvent Reservoir, Pump, Injector, Column, Detector, And Data Recording System. Particles And Microbial Growth That Are Not Removed By Filtration Interfere With Nearly Every System Component.
The Stainless Steel Filter Holders Are Designed To Ultraclean Or Sterilize Liquids & Mobile Phase Solvents By Vacuum Filtration. SS 316 -Faced Support Screens Permit Autoclaving With Membranes In Place.
For Use When Using A Vacuum Source To Filter Liquids Into A Filter Flask
Filter Provides An Effective Filtration Of 46.5 Cm²
Designed To Maximise Flow And Reduce Foaming
Assembly Includes:
1000 Ml SS316 Funnel
Highly Integrated Sealed 90 Mm SS Support Base
2000 Or 5000 Ml Flask
Aluminum Clamp Holds The Filter Funnel And Support Base Properly
₹ 48000 / Piece Get Latest Price
| Filter Diameter | 47 mm |
| Material | Stainless Steel |
| Connection Type | Vacuum |
| Size | 47 mm |
| Brand | aone |
| Country of Origin | Made in India |
| Filter Funnel | S.S.316 With Inbuilt S.S. Clamp |
| Material of Manifold | S.S. With PTFE Valve / 2-Way |
| Branches available | 1,3,6 Stage |
| Membrane Filter | 47 mm/0.45 Mm Pack Of 100 |
| Vacuum Flask | 2 Litre |
| Vacuum Pump | Diaphragm Type-Oil Free Vacuum Pump |
| Air Vent Filter | Hydrophobic PTFE 50 mm/ 0.2mm |
Minimum order quantity: 1 Piece
₹ 15500 / Piece Get Latest Price
| Membrane dia | 47 mm |
| Funnel volume | 250 ml |
| Material | Polysulfone |
| Usage/Application | Laboratory |
| Brand | aone |
| Capacity | 300 ml |
| Filter Size | 47 mm |
| Seal | Silicon |
Minimum order quantity: 500 Piece
₹ 12500 / Piece Get Latest Price
| Material | Stainless Steel |
| Usage/Application | Laboratory |
| No of Branches | 1 / 3 / 6 Stage |
| Membrane Diameter | 47 mm |
| Filtration Area | 13.5 Cm2 |
| Supported Funnels | s s / glass |
Minimum order quantity: 10 Piece
₹ 42500 / Piece Get Latest Price
| Material | SS 316 |
| Usage/Application | Laboratory |
| Membrane | 47mm x 0.45um Cellulose Nitrate Membrane FIlter Paper |
| Filter Head | 6 Stage |
| Oil Free Vaccum Pump | AE 75 S |
| Filter Funne | S.S.300ml with External Aluminum Clamp |
| Material of Manifold | S.S. With PTFE Valve / 2-Way |
| Air Vent Filter | Hydrophobic PTFE 50 mm/ 0.2mm |
Minimum order quantity: 10 Piece
₹ 31800 / Piece Get Latest Price
| Material | Stainless steel 316 |
| ss- | SS-316 Filter Funnel 300ml {Duck-Clamp} |
| vacuum- | Oil Free Vacuum Pump AE45s for 3 Stage |
| Borosilicate- | Vacuum Trap / Borosilicate flask with Silicon Tube - 2mt. |
Minimum order quantity: 1 Piece
• SS-316 Filter Funnel 300ml
• Vacuum Flask 2 Ltr.
• Oil Free Vacuum Pump AE45s for 3 Stage
• Oil Free Vacuum Pump AE75s for 6 Stage
• Air Vent Filter PTFE 50mm / 0.2um
• 47mm x 0.45um Cellulose Nitrate Membrane FIlter Paper
• Vacuum Trap / Borosilicate flask with Silicon Tube – 2m.
• Forceps.
₹ 65000 / Piece Get Latest Price
| Pump Type | Diaphragm |
| Flow Rate(Litre/Minute) | 10 LPM |
| Pumping Speed | 1 m³/h |
| Ultimate Vacuum | 1 mbar |
| Surface Finish | Mirror Finish |
| Usage/Application | Laboratory Filtration , Microbiology Test , Sterility Test |
| Material Grade | SS 316 L |
| Filter Size | 47 mm |
| Capacity | 300 ml |
| Receiver | 1000 ml |
Minimum order quantity: 1 Piece
₹ 2200 / Piece Get Latest Price
| Capacity | 1L |
| Material | Glass, Silicone |
| Vacuum trap | Glass / Polypropylene |
| Application | Laboratory |
Minimum order quantity: 1 Piece
₹ 14500 / Piece Get Latest Price
| Material | Borosilicate Glass |
| Top Diameter | 100 mm |
| Capacity | 500 ml funnel capacity , Receiver 2000ml |
| Usage/Application | Chemical Laboratory |
Minimum order quantity: 1 Piece
Buchner funnels are used in the laboratory for vacuum-assisted liquid filtering. In organic chemistry, these funnels are used to collect recrystallized compounds because they help remove moisture from the final product.
Buchner funnels consist of an open straight-sided cylindrical chamber that narrows to a tube- or pipe-shaped opening. The tube-like extension can be placed through a stopper, which is then placed into the top of a filtration or Buchner flask. Plastic versions may have a bung hole located at the side of the chamber to which a vacuum may be attached. Buchner funnels are reusable.
The bottom of the Buchner funnel chamber may be perforated or contain a separate fritted disc. Filter paper is used for Buchner funnels with perforated lower surfaces. Place the filter paper of the preferred porosity inside the chamber, pre-wet, add the liquid, and apply the vacuum.
Funnels with fritted glass discs do not require filter paper. The fritted glass will be porosity-rated as fine, coarse, medium, etc. Filtration with a Buchner funnel proceeds more quickly than letting the liquid flow simply using gravity. Most Buchner funnels are also rated for a maximum vacuum pressure.
₹ 32000 / Piece Get Latest Price
| Material | Stainless Steel |
| Model | GMP |
| Usage/Application | Laboratory |
| Brand | A One |
| Country of Origin | Made in India |
| No of Branches | 1 / 3 / 6 |
| Membrane Diameter | 47 mm Effective |
| Filtration Area | 13.5 Cm2 |
| Supported Funnels | Polypropylene |
| Supported Volume Of Funnel | 300 ml |
Minimum order quantity: 2 Piece
They have been designed specifically for applications in which the particles or microorganisms retained on the membrane filter surface are of interest. Simple handling is very important regarding routine examinations. Stainless steel taps in the base allow the vacuum to be turned on and off. Stainless steel and PP funnel, SS funnel & glass funnel for choice.
Optional :
Diaphragm Vacuum Pump, Sterile Membrane, Flame Sterilization Tool, Tweezer, Flask Fittings
Mahesh Thakur (Owner)
A-One Engg. Works
2nd Floor, Gala No 2073, Bhandup Industrial Estate, Pannalal Compound, LBS Marg, Bhandup West
Mumbai - 400078, Maharashtra, India